Huge savings made at leachate treatment plant

At a landfill’s leachate treatment centre, where floating biomass was reducing the plant’s throughput, the introduction by Viridian Systems of a new mixer has created annual savings on chemicals of around £85,000.

From sludge taking well over two hours to settle (with unnecessary amounts still floating), it has now been reduced to less than 30 minutes. With the plant set up for two batches per day, this potentially adds back three hours of treatment time per day, which equates to more than 14,000m3/year of leachate that no longer has to be tankered off site: equating to a further annual saving of £285,000.

As Viridian Systems’ Managing Director, Roger Dixon explains, the new mixer (made by Landia) has now completely eliminated the problematical filamentous bacteria.

‘The right amount of agitation’

“To solve the problem for the leachate treatment plant”, he said, “we believed that with the correct type of mixer; suitably positioned, powered and timed, the right amount of agitation would disperse the floating layer to allow solids to settle much more quickly”.

‘No more floating biomass’

He added: “Undesirable filamentous bacteria, which is one of the main causes of floating biomass, is detrimental to SBRs, but working closely together with Landia, who have vast experience in mixer applications, the sub-surface liquor is now degassed; meaning no more floating biomass”.

As the plant began to produce far less unwanted foam, Birkenhead-based Viridian Systems asked the plant operator to gradually reduce dosing with de-foaming agent (antifoam) until the consumption rate falls to around 1-2 drums/month, instead of 2-3 drums/day, which will not only save around £70-100k/year but will also reduce the dissolved organics (measured as chemical oxygen demand C.O.D.) in the treated effluent.

Furthermore, the installation of the Landia mixer has also enhanced the reliability of the plant’s Dissolved Oxygen (D.O.) (optical) probe, because there is less foam to blind it. With the probe now working as it should, there is better control of the blower speed, reducing its energy consumption, which in turn, offsets some of the power consumed by the mixer.

Viridian Systems’ Roger Dixon concluded: “Far from just supplying a mixer, Landia shared our goal in wanting to find the best possible solution. What has been achieved provides considerable ongoing benefits for our customer. As a result of this success, we have also installed a Landia mixer in a tank adjacent to the SBR”.

NEWS CATEGORIES

LATEST NEWS

Polluting water bosses face up to two years in prison

Water company bosses could face up to two years in prison due to new powers in force today, Friday 25 April 2025.   The new powers,...

Regulators have failed to deliver a trusted and resilient water sector, says the National Audit Office

The Department for Environment, Food and Rural Affairs (Defra) and water regulators have failed to drive necessary investment for the sector in the past...

Water UK calls for major reform in submission to Independent Water Commission

Water UK, the trade association representing all of the water and wastewater companies across Scotland, England, Wales and Northern Ireland, is calling for major reform...

Richard Benwell, CEO of Wildlife and Countryside Link, tells government committee that nature isn’t a blocker to development, but should be a partner

The Public Bill Committee on the Planning and Infrastructure Bill met for the first time yesterday (Thursday 24 April 2025). The committee heard oral evidence...