Huge savings made at leachate treatment plant

At a landfill’s leachate treatment centre, where floating biomass was reducing the plant’s throughput, the introduction by Viridian Systems of a new mixer has created annual savings on chemicals of around £85,000.

From sludge taking well over two hours to settle (with unnecessary amounts still floating), it has now been reduced to less than 30 minutes. With the plant set up for two batches per day, this potentially adds back three hours of treatment time per day, which equates to more than 14,000m3/year of leachate that no longer has to be tankered off site: equating to a further annual saving of £285,000.

As Viridian Systems’ Managing Director, Roger Dixon explains, the new mixer (made by Landia) has now completely eliminated the problematical filamentous bacteria.

‘The right amount of agitation’

“To solve the problem for the leachate treatment plant”, he said, “we believed that with the correct type of mixer; suitably positioned, powered and timed, the right amount of agitation would disperse the floating layer to allow solids to settle much more quickly”.

‘No more floating biomass’

He added: “Undesirable filamentous bacteria, which is one of the main causes of floating biomass, is detrimental to SBRs, but working closely together with Landia, who have vast experience in mixer applications, the sub-surface liquor is now degassed; meaning no more floating biomass”.

As the plant began to produce far less unwanted foam, Birkenhead-based Viridian Systems asked the plant operator to gradually reduce dosing with de-foaming agent (antifoam) until the consumption rate falls to around 1-2 drums/month, instead of 2-3 drums/day, which will not only save around £70-100k/year but will also reduce the dissolved organics (measured as chemical oxygen demand C.O.D.) in the treated effluent.

Furthermore, the installation of the Landia mixer has also enhanced the reliability of the plant’s Dissolved Oxygen (D.O.) (optical) probe, because there is less foam to blind it. With the probe now working as it should, there is better control of the blower speed, reducing its energy consumption, which in turn, offsets some of the power consumed by the mixer.

Viridian Systems’ Roger Dixon concluded: “Far from just supplying a mixer, Landia shared our goal in wanting to find the best possible solution. What has been achieved provides considerable ongoing benefits for our customer. As a result of this success, we have also installed a Landia mixer in a tank adjacent to the SBR”.

NEWS CATEGORIES

LATEST NEWS

Joint research on engagement and accountability published by CCW and Ofwat

Joint research by the Consumer Council for Water (CCW) and Ofwat, has been published, exploring the themes of consumer engagement with water companies and...

Prolonged dry conditions increase water scarcity across Scotland

The Scottish Environment Protection Agency (SEPA) has confirmed that Scotland’s water scarcity situation is worsening, with a further decline in river levels following another...

NRW steps up action in response to prolonged dry weather

Following the extended period of warm and dry weather, Natural Resources Wales (NRW) has confirmed that the trigger thresholds have been met to move...

£6m funding for automated drones and smart robotics that will be able to both sample and deliver near lab-grade analysis of coastal and inland...

A world-leading project that’s set to see drones, robots and a mobile lab transform how rivers and seas are monitored has been named a...